SYEC

XHK-Ⅱ型消弧线圈自动调谐及接地选线成套装置

使用说明书

(Ver.2.0C)

上 海 思 源 电 气 股 份 有 限 公 司

SHANGHAISIYUANELECTRICCO.,LTD.

目 录

一、概述·························································

1

二、技术参数···················································

2

三、型号说明···················································

3

四、结构及组成原理··········································

3

4-1接地变压器·········································

3

4-2有载消弧线圈·······································

4

4-3自动调谐及选线控制器···························

6

4-4阻尼电阻控制箱····································

8

4-5中性点电压互感器·································

9

4-6隔离开关·············································

9

4-7控制屏················································

9

五、面板布置···················································

9

六、操作说明···················································

9

6-1菜单结构·············································

10

6-2菜单项说明··········································

10

6-3故障及报警显示····································

19

七、运行维护注意事项·······································

21

7-1总则···················································

21

7-2正常运行时注意事项······························

21

7-3系统单相接地时注意事项························

23

7-4装置异常时注意事项······························

23

7-5维护注意事项·······································

23

八、售后服务···················································

24

九、订货须知···················································

24

十、附录·························································

25

XHK-II型消弧线圈自动调谐及选线成套装置使用说明书

XHK-II型消弧线圈自动调谐及选线成套装置使用说明书

SYEC

第PAGE1

第PAGE1页

版本:

Ver.

2.0C

一、概述

随着国民经济的迅速发展和电力系统容量的不断扩大,电力电网的安全运行和供电的可靠性越来越重要,而直接影响以上两个指标的是电网中性点接地方式的选择。

长期以来,我国6~66kV的配电网大多采用中性点不接地运行方式。这种运行方式,由于在单相接地时允许短时间内带故障运行,因而大大提高了供电的可靠性。然而,随着城乡电网的大规模改造,系统对地电容电流急剧增加,单相接地后流经故障点的电流增大,容易产生过电压幅值很高的间隙性弧光接地。同时,由于电磁式电压互感器铁芯饱和时容易引起谐振过电压,导致事故跳闸率明显上升。

为了解决上述问题,不少电网采用了谐振接地方式,即在中性点装设消弧线圈,当发生单相接地时,由于消弧线圈产生的感性电流补偿了故障点的电容电流,因而使故障点的残流变小,电网能够自然熄弧,防止事故扩大,消除事故隐患。运行经验表明,消弧线圈对抑制间隙性弧光过电压及电磁谐振过电压、降低线路的事故跳闸率、减少人身伤亡和设备的