The greater the pulse width, the shorter the battery longevity. An increase in pulse width leads to an increase in total energy delivered. The longer the duration of the stimulus, the lower the amplitude required to capture the heart The strength-duration curve illustrates the tradeoff of amplitude (intensity of stimulation, measured in volts) and duration (the length of time the stimulation is applied, measured in milliseconds). Capture occurs when the stimulus causes the tissue to react. On the graph, capture occurs on or above the curve. Anything below the curve will not capture. The lowest voltage on a stimulation curve which still results in capture at an infinitely long pulse duration is called rheobase. A voltage programmed below is inefficient and will lead to non-capture. The pulse duration at twice the rheobase value is defined as the chronaxie. Chronaxie time is typically considered most efficient in terms of battery consumption. Safety margins have traditionally been selected as follows, when a threshold is determined by decrementing the pulse width at a fixed voltage: At a given voltage where the pulse width value is .30 ms: Tripling the pulse width will provide a two-time voltage safety margin. Pulse widths at a given voltage value which are .30 ms are not typically selected, because they are less efficient (expend more energy), while not providing further safety. In this case, the voltage should be doubled to provide a two-time safety margin. Adequate safety margins must be selected due to daily fluctuations in threshold that can occur due to eating, sleeping, exercise, or other factors that affect thresholds. Also, a patient with an acute pacing system will typically be programmed to a setting allowing a higher safety margin, due to the lead maturation process, which can occur within the first 6-8 weeks following implant. Most lithium-iodine batteries (those used most often in pacemakers today), the battery voltage is 2.8 V at the beginning o

文档评论(0)

191****0059 + 关注
官方认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:5342242001000034
认证主体四川龙斌文化科技有限公司
IP属地四川
统一社会信用代码/组织机构代码
91510100MA6ADW1H0N

1亿VIP精品文档

相关文档