PCS7 CFC编程培训(内部工程师培训).ppt

  1. 1、本文档共127页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Multiple Instance The FB602 is structured so that another, already existing FB40 can be called within it. This FB is detected as static variable with the data type FB and allows to achieve nesting of variables and concentration of all instance data in one instance data block (multiple instance). Structure If you want to look at the structure of your new block, proceed as follows: - In the block folder of your library, select FB40 (INT_P), then RMC: and choose Open Object. LAD/STL/CSF is opened. - Close the block only via File - Close (Do not save, if you are prompted to save!) - In this editor open your block FB602 (V_SIM) with RMC: Object - Open Now you can see the above structure on your screen. Attributes - Position the mouse pointer in a line (with green marking), then activate RMC: Object properties - Attributes to display the table with attributes (properties) of the parameter. Changes If you change/supplement attributes here, and then save the block, it will be given an STL identification. The changes must be made known to the CFC (if the block has already been used). Further consequences arise from the type of modified attributes. 块改变(1.4) The new block version is transferred to the chart folder 块调整 (2) 块调整(2.1) 库和项目调整的块改变 (2) 库和项目调整的块改变(3) The new block version is transferred to the project AS-to-AS 通讯 反应器加热的 控制器 SP_EXT SP AS-to-AS Communication 通讯块连接 SEND_R REC_R REC_R SEND_R OP_EN U_HL U_LL LINK_U LINK_ON BTRACK U OP_A_LIM Interconnectable input for U Operator input analog Operator enable Limits V 接收到的给定可被处理 Partner A Partner B AS-to-AS通讯的通讯块 Partner 1 Partner 2 or Partner 1 Partner 2 Exercise In the plant view, you want to insert a test CFC chart with the above function in the Reactors/Test folder. Both blocks are to run in OB32. The first block type is PT1_P (time-delay element of the 1st order) and the second block type is ADD4_P (adder). Create, compile, download and test the chart. Steps 1. Call the project in plant view.

文档评论(0)

知识的天空 + 关注
实名认证
内容提供者

电子工程技术工程师持证人

推荐自动化、电气、仪表、工程、医学等精品培训教程

领域认证该用户于2023年06月07日上传了电子工程技术工程师

1亿VIP精品文档

相关文档