水泵台数的选择及把持方法(国外英文资料).doc

水泵台数的选择及把持方法(国外英文资料).doc

  1. 1、本文档共4页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
水泵台数的选择及把持方法(国外英文资料)

水泵台数的选择及控制方式(国外英文资料) Selection and control of pump stage number 1, principle: for not artificially controlled or artificial control of serious consequences will be produced after collecting well (fire water drainage, rainwater), should consider to set up the standby pump, other sump pump is generally not equipment. But all water Wells need to set the alarm water level of three kinds: stop pump water level, first (second, third...). Pump water level, overflow (spare pump pump) water level Lead to the property management center. 2, for the rainwater collecting well, no matter for bike ramp, or ramp, all needs to set up a spare pump, and because of the rain return period of random, backup automatically when the pump should be in the water level alarm input, is like a water pump for dual-use preparation and above, should by Taiwan, close by. Only two drainage pumps in the current specification of water pump house or fire water pump are the fire pump. Because although the specification only requires 10L/s, the amount of water is much more than 10L/s when the fire is on fire, so the spare pump is required to start automatically when the alarm water level is in place. 4, basement, equipment room (such as living water pump room), such as shop floor washing waste water pump well, the standby pump does not need to start when water level alarm, if there is a set of two or more Wells, dont consider pump equipment, such as well to the rolls without the rest of the season, the collecting well combined drainage, fire fighting pump, pump well and control should be in accordance with the fire pump well consideration. In particular, the pump and control should be considered according to the fire collection well, especially for the waste well of the lower part of the basement, such as the pump room due to the laminar shortage. To reduce the water pump discharge and increase the number of pumps, in order to satisfy the requirement of the maximum capacity of the collecting well and not

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档